Excavator attachment supply · Ningbo, China Search · FAQ · Support · Market / EnglishWhatsApp +86 15058273161
WE-ATTACH

Accessories & Wear Parts

Automatic Grease Device

MODEL AGD-H2

AGD-H2 automatic grease device for breaker lubrication. Share your breaker and lubrication requirements to review the setup.

Identify the parent breaker, lubrication port, device mounting direction and hose route. Keep the grease outlet connected to the designated lubrication point shown in the source.

Output Pressure,Bar
18-164
Product view from the supplied catalogue.

FROM AN IDEA TO A REQUIREMENT

What to specify for this attachment

Use these decisions to turn the work requirement into a model and configuration enquiry.

Information to carry into the review
DecisionWhy it mattersInformation to provide
Applicable attachmentAn accessory must be identified against the installed product.Full model/suffix, installation and part/drawing identity.
Connections and conditionsPorts, medium and service conditions must match the configuration.Connection details, operating conditions and requested documents.
Revision and maintenanceA visually similar item is not enough to confirm interchangeability.Current revision, part reference and the required service information.
View the supplied catalogue drawing and original technical page

Supplier-provided catalogue reference · P03 physical page 51. Check the exact model header, configuration and source version. This excerpt is not a substitute for the current approved installation drawing or a model-specific test report.

Original supplied catalogue technical page 51

Catalogue specifications and source

Original units retained; not a machine compatibility approval
FieldCatalogue referenceSource physical page
ModelAGD-H2P03 · p.51 ↗
OUTPUT PRESSURE,BAR18-164P03 · p.51 ↗
CARTRIDGE CAPACITY,ML400P03 · p.51 ↗
EXTERIOR SIZE,MM165*88*252P03 · p.51 ↗
WEIGHT WITHOUT GREASE,KG3.9P03 · p.51 ↗
OUTPUT PORT SIZEPF1/4P03 · p.51 ↗
RUNNING TIME OF CARTRIDGE (NORMAL CONDITION)As printed: 500CC/100CC 1HOUR → 1 OR 2 CARTRIDGES 1 DAY; 0CC/22CC 1HOUR → 1 CARTRIDGE 3-5 DAYS. Catalogue examples; dosing notation and applicability require confirmation.P03 · p.51 ↗
GREASE TYPEPLEASE USE BELOW 200CST VISCOSITY GREASEP03 · p.51 ↗
NORMAL TEMPERATURE RANGE-10℃-70℃P03 · p.51 ↗
PERMISSIBLE TEMPERATURE RANGE-10℃-70℃P03 · p.51 ↗

Drawing letters such as A/B refer to the original drawing keys; verify dimensions and units with the current model drawing.

Purpose and task

AGD-H2 is the automatic grease device reference for breaker lubrication. Provide a separately specified lubrication arrangement for the applicable breaker installation.

How this helps your buying decision

Identify the parent breaker, lubrication port, device mounting direction and hose route. Keep the grease outlet connected to the designated lubrication point shown in the source. Compare AGD-H2 with AGD-Z5 as separate source-listed configurations. For WEIGHT WITHOUT GREASE,KG, the listed values are 3.9 (AGD-H2) and 3.9 (AGD-Z5). For OUTPUT PRESSURE,BAR, the listed values are 18-164 (AGD-H2) and 20-60 (AGD-Z5). Keep units, mounting position, circuit labels and document conditions with each value. Similar model numbers or overlapping carrier references do not prove fitment, interchangeability or a better result for your task.

Model and configuration

The model-specific source row states: OUTPUT PRESSURE,BAR: 18-164; CARTRIDGE CAPACITY,ML: 400; EXTERIOR SIZE,MM: 165*88*252; WEIGHT WITHOUT GREASE,KG: 3.9; OUTPUT PORT SIZE: PF1/4; RUNNING TIME OF CARTRIDGE (NORMAL CONDITION): As printed: 500CC/100CC 1HOUR → 1 OR 2 CARTRIDGES 1 DAY; 0CC/22CC 1HOUR → 1 CARTRIDGE 3-5 DAYS. Catalogue examples; dosing notation and applicability require confirmation.; GREASE TYPE: PLEASE USE BELOW 200CST; VISCOSITY GREASE; NORMAL TEMPERATURE RANGE: -10℃-70℃; PERMISSIBLE TEMPERATURE RANGE: -10℃-70℃. Retain the printed units, dimension keys and applicable circuit or mounting labels; unknown drawing units require confirmation rather than conversion.

Machine and interface review

Identify the parent breaker, lubrication port, device mounting direction and hose route. Keep the grease outlet connected to the designated lubrication point shown in the source.

Installation, control and operating conditions

Match the drive mechanism and lubricant outlet to the parent breaker and lubrication drawing. The printed output-pressure row is not a hydraulic supply specification. Confirm dosing adjustment, device mounting direction, hose route, grease grade and working temperature. AGD-H2 is labelled hydraulic drive type and AGD-Z5 mechanical type. Outlet pressure is not the excavator supply rating. Source cartridge examples and grease-temperature wording need confirmation for actual dosing and duty.

Structure and differences

The supplied table separates cartridge capacity, exterior size, outlet connection, grease and temperature conditions. AGD-H2 is labelled hydraulic drive type and AGD-Z5 mechanical type. Outlet pressure is not the excavator supply rating. Source cartridge examples and grease-temperature wording need confirmation for actual dosing and duty.

Application boundaries

Brochure cartridge running-time examples are not a universal maintenance interval; installation and grease requirements remain device/model-specific. Preserve the printed dosing notation and grease guidance. H2 cartridge examples differ between P03 and P04; Z5 grease recommendations repeat the same below-10°C condition for two grades. Obtain clarified lubricant/dosing instructions before selecting a service interval.

Manufacturing and quality responsibility

WE-ATTACH supports attachment selection, configuration requirements and coordinated supply through core manufacturing partners, with a warehouse and hillside testing site. Keep the actual manufacturer, ordered model and applicable scope with inspection, material or compliance records. A partner facility certificate or catalogue image is not model-specific product approval.

Documents, parts and operation

Use P03 physical PDF page 51; P04 physical PDF page 13 and the model-reference CSV linked on this page. Each exported parameter retains its source ID and physical page. Catalogue sketches, source images and selection tables are reference information; request the current mounting/connection drawing, operating and maintenance instructions and model-specific evidence for the actual ordered configuration. The separate source-version download retains unresolved descriptions; agree which revision applies rather than combining convenient values.

Options and scope of supply

Specify the device, cartridge, approved lubricant, mounting/hose kit and service instructions; do not assume an electric or battery drive. Have the quotation identify the attachment, mounting, controls/connections, included accessories and required parts individually. A pictured option, support frame or related tool is not automatically included.

Information to send with a AGD-H2 enquiry

For AGD-H2, send the parent breaker identity, device drive, grease grade/temperature and duty; lubrication connection and mounting details; Parent breaker; device drive; output connection; grease type; temperature and duty. Include quantity, destination and any drawings/photos. State units and identify unknown values rather than substituting a similar machine or model.

Before confirming the order

Agree the complete model and suffix, actual machine, interfaces, operating conditions and scope of supply. Keep unresolved source descriptions and accepted drawing/document revisions with the quotation. Confirm inspection/document requirements, price, delivery, warranty and service scope for the actual order; no unverified term or performance commitment is added here.

Source and document traceability

Catalogue transcription for preliminary review. Confirm the applicable configuration and current approved revision before order.

Applications and working conditions

Selection and purchase guides

Questions before selection

What task does AGD-H2 address?

AGD-H2 is the automatic grease device reference for breaker lubrication. Provide a separately specified lubrication arrangement for the applicable breaker installation.

Which information should accompany a AGD-H2 enquiry?

For AGD-H2, send the parent breaker identity, device drive, grease grade/temperature and duty; lubrication connection and mounting details; Parent breaker; device drive; output connection; grease type; temperature and duty. Include quantity, destination and any drawings/photos. State units and identify unknown values rather than substituting a similar machine or model.

What must be checked before confirming this configuration?

Brochure cartridge running-time examples are not a universal maintenance interval; installation and grease requirements remain device/model-specific. Preserve the printed dosing notation and grease guidance. H2 cartridge examples differ between P03 and P04; Z5 grease recommendations repeat the same below-10°C condition for two grades. Obtain clarified lubricant/dosing instructions before selecting a service interval.

How should I compare AGD-H2 with another configuration?

Compare AGD-H2 with AGD-Z5 as separate source-listed configurations. For WEIGHT WITHOUT GREASE,KG, the listed values are 3.9 (AGD-H2) and 3.9 (AGD-Z5). For OUTPUT PRESSURE,BAR, the listed values are 18-164 (AGD-H2) and 20-60 (AGD-Z5). Keep units, mounting position, circuit labels and document conditions with each value. Similar model numbers or overlapping carrier references do not prove fitment, interchangeability or a better result for your task. AGD-H2 is labelled hydraulic drive type and AGD-Z5 mechanical type. Outlet pressure is not the excavator supply rating. Source cartridge examples and grease-temperature wording need confirmation for actual dosing and duty.

What installation and operating information is needed for AGD-H2?

Identify the parent breaker, lubrication port, device mounting direction and hose route. Keep the grease outlet connected to the designated lubrication point shown in the source. Match the drive mechanism and lubricant outlet to the parent breaker and lubrication drawing. The printed output-pressure row is not a hydraulic supply specification. Confirm dosing adjustment, device mounting direction, hose route, grease grade and working temperature.

Where can I check the source and current documents for AGD-H2?

Use P03 physical PDF page 51; P04 physical PDF page 13 and the model-reference CSV linked on this page. Each exported parameter retains its source ID and physical page. Catalogue sketches, source images and selection tables are reference information; request the current mounting/connection drawing, operating and maintenance instructions and model-specific evidence for the actual ordered configuration. The separate source-version download retains unresolved descriptions; agree which revision applies rather than combining convenient values.

Which parts and options should the AGD-H2 quotation identify?

Specify the device, cartridge, approved lubricant, mounting/hose kit and service instructions; do not assume an electric or battery drive. Confirm the exact configuration and each included item rather than using a family illustration as a packing list.

Related model references

Parameter versions requiring confirmation

These source descriptions are shown side by side. They have not been merged into one approved specification; unaffected catalogue fields are retained above.

Original source variants · physical PDF page numbers
FieldSource description ASource description B
Cartridge runtime example, second conditionP03 physical page 51: 1 CARTRIDGE / 3-5 DAYSP04 physical page 13: 1-3 CARTRIDGES / 3-5 DAYS; confirm source wording and dosing condition

Where this tool fits in the work.

Discuss AGD-H2 with your project conditions

Missing a technical value? Describe what is available so the next information needed can be identified.

CONTINUE YOUR REVIEW

Related information for your next decision

Discuss your machine, application and configuration →

What do you need to do?

Start with part of a model or describe the job. Suggested results are for selection review.